Concrete mixing plant concrete mixing plant mainly by the mixing console, material weighing system, material handling systems, material storage systems and control systems and other five major system components and other ancillary facilities.
2013年8月16日星期五
Block making machine system allows the minimum oil temperature is 25 ℃
Concrete block machine system allows the minimum oil temperature was 25 ℃. Optimal operating temperature of 35℃ -45 ℃, exceed 45 ℃ is detrimental to the system. If the value exceeds the specified response systems Conduct a review Yao, and remove.
To ensure that the electrical system to work, we must maintain voltage stability, its value does not fluctuate Should be more than or less than the rated voltage of 5-10%.
Electrical cabinets, junction boxes, console, door or lid must be closed when the machine is working on Or cover, not allowed to open use, so the contamination.
When the hydraulic system failure (for example, does not operate normally, hydraulic instability, hydraulic Too low, concrete mixing machine, temperature rise too fast, etc.), to promptly analyze the reasons for discharge In addition to failure, allowing the machine to work sick, causing a major accident.